8)Connect the FNS IF cable (4 pin white connector) coming from the Container Stacker 2 to the J680 on the ST09X P/K of the Container Stacker 1. (Connection 1 on the below figure)

9)Take out the CSTAC cable (2 pin white connector) from the Container Stacker 1 and connect it to the CSTAC cable (2 pin white connector) of the Container Stacker 2. (Connection 2 on the below figure)

10)Take out the RB cable (4 pin white connector) from the Container Stacker 1 and connect it to the RB cable (4 pin white translucence) of the Container Stacker 2. (Connection 3 on the below figure)

11)Mount the CST FG cable coming from the Container Stacker 1 on the frame of the Container Stacker 2 by using M4 screw (Connection 4 on the below figure).

12)Turn on the No. 4 and 5 and turn off the No. 2 and 8 of the SW1 mounted on the CPXXX P/K of the Engine. (No RoHS Compliance Unit)

13)Turn on the No.4 and 5 and turn off the No.2 and 8 of the SW1 mounted on the CPXXX P/K of the Engine. Turn off the No.7 and 8 of the SW2 mounted on the CPXXX P/K of the Engine.

(RoHS Compliance Unit)

[Note] Put the cable through the opening “A” of the Engine for connection.

RB cable

(For Container Stacker 2)

Engine

14)

Connection 3

RB cable

(For Container Stacker 1)

 

 

(4 pin white)

 

 

AF cable

 

 

 

 

 

 

 

 

 

 

Container Stacker 2

 

 

 

 

Container Stacker 1

(W/ Through path)

 

 

 

(W/ Sample tray)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Connection 2

Opening “A”

Connection 1

M4 screw

(2 pin white)

 

 

(20 pin black)

Connection 4

CST FG cable

CST AC cable

Disconnection 2

 

(2 pin white)

Disconnection 1(4 pin white)

No RoHS Compliance

Unit

OFF

 

ON

 

 

 

 

OFF

1 2 3

MKK

4 5 6 7 8

SW2

OFF

 

ON

 

 

 

 

OFF

1 2 3

MKK

4 5 6 7 8

SW1

RoHS Compliance Unit

 

II

L

001

 

 

Preparation for Installation 4-35

Page 83
Image 83
Ricoh 70E installation manual RoHS Compliance Unit