SATO GT 410, GT 424e, GT408 Interface Selection, RS232C SERIAL INTERFACE, RS232C SPECIFICATIONS

Models: GT 410 GT408 GT 424e

1 106
Download 106 pages 5.28 Kb
Page 20
Image 20
INTERFACE SELECTION

Unit 3: Installation

INTERFACE SELECTION

This chapter presents the printer interface types and their specifications. These specifications include detailed information to assist in the selection of the most appropriate method for the printer to interface with the host. The four acceptable interface methods are:

RS232C Asynchronous Serial

IEEE1284 Parallel

Universal Serial Bus (USB) Adapter

Local Area network (LAN) Ethernet

802.11B Wireless

Following the selection of the desired interface, proceed to the following unit for instructions on how to Configure the printer for that interface type.

WARNING: NEVER CONNECT OR DISCONNECT INTERFACE CABLES (OR USE A SWITCH BOX) WITH POWER APPLIED TO EITHER THE HOST OR THE PRINTER. THIS MAY CAUSE DAMAGE TO THE INTERFACE CIRCUITRY IN THE PRINTER/HOST AND IS NOT COVERED BY WARRANTY.

NOTE: Some hosts monitor the Request-To-Send (RTS) signal (pin 4 of 25) to determine if the printer is ready to receive data. Since the printer does not generate this signal, the RTS line must be held true (high) in order to allow communication. This can be performed by connecting the RTS pin to the Clear-To-Send (CTS) signal (pin 5 of 25).

RS232C SERIAL INTERFACE

This High Speed Serial Interface is a Plug-In Interface Module that can be installed in the printer by the user. The only difference between this interface and the TTL is their signal levels and cable pinouts.

 

RS232C SPECIFICATIONS

Asynchronous ASCII

 

Half-duplex communication

 

 

Bi-Directional Communication

Data Transmission Rate

 

9600, 19200, 38400, 57600 bps

Data Length

 

8 bit (selectable)

Stop Bit

 

1 bit (fixed)

Parity Bit

 

ODD, EVEN, NONE (selectable)

Codes Used

 

ASC II Character Codes, JIS Kanji Codes

Control Codes

 

STX (02H), ETX (03H), ACK (06H), NAK (15H)

Connector

 

Special

Cable

 

Special

Signal Levels

 

High = +5V to +12V, Low = -5V to -12V

SATO GT4xxe Series Operator Manual

PN 9001138A

Page 3-6