Sharp ER-A440S instruction manual Functional programming PGM 2, Compulsory item validation print

Models: ER-A440S

1 164
Download 164 pages 49.2 Kb
Page 37
Image 37

4Programming for departments

Your machine is equipped with 20 standard departments and up to 50 optional departments. Your machine allows you to perform the following programming for each department:

Functional programming PGM 2 2110

You can set each department for:

Compulsory item validation print

If item entries must be validated, program corresponding departments for compulsory item validation print.

SICS (Single Item Cash Sale) / SIF (Single Item Finalization)

SICS

If the first registration is to a department set for SICS, the sale is finalized as soon as the department key is

pressed. If the sale is preceded by registrations to departments not set for SICS, a sale to a department set for SICS does not finalize and can be repeated until the ;key is pressed.

SIF

Whenever a sale is made to a department set for SIF, the sale is finalized as soon as the department key is pressed.

Type of unit price entry

You may select one of the following four types of unit price entry for each department.

Open and preset

Preset only

Open only

Inhibit department key

Procedure

To program for the dept. other than the following dept.

c

To keep the current setting

 

 

.

 

 

 

 

 

 

 

 

 

 

 

 

:

 

 

;

2110

 

 

 

 

Dept. code

 

 

 

 

 

 

*ABCDEFG

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

To program for the following dept.

 

 

 

 

 

 

 

 

 

 

The current

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

setting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

is displayed.

 

 

 

 

 

 

* Item:

 

 

 

 

 

 

 

Selection:

 

 

Entry:

 

A

Always enter 0.

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

B

Item validation print

 

 

 

Compulsory

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

Non-compulsory

 

0

 

 

 

 

C and D Always enter 0.

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

E

SIF/SICS /Normal

 

 

 

SIF

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

SICS

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

Normal

 

0

 

 

 

 

F

Always enter 0.

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

G

Type of unit price entry

 

 

 

Open and preset

 

3

 

 

 

 

 

 

 

 

 

 

 

 

 

Preset only

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

Open only

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

Inhibit department key

0

 

 

 

35