Specifications

Specifications

Technical Specifications: SITRANS LC 500

Power

Supply voltage

 

maximum:

33 Vdc, (30 Vdc for IS)

minimum

12 Vdc at 3.6 mA (9.5 Vdc at 22 mA)

Loop current

3.6 to 22 mA / 22 to 3.6 mA (2-wire current loop)

Environmental

Location

indoor/outdoor

Altitude

2000 m max.

Ambient temperature

 

standard:

–40 oC to 85 oC (–40 oF to 185 oF)

ATEX-Explosion Proof

–40 oC to 70 oC (–40 oF to 158oF) for T6

 

 

–40 oC to 85 oC (–40 oF to 185 oF) for T5 to T1

Relative humidity

suitable for outdoor (Type 4X / NEMA 4X / IP 65

 

 

enclosure)

Installation category

II

Pollution degree

4

Performance

Measurement range

 

MSP-2002-2

0 to 3300 pF

Minimum span

3.3 pF

Measurement frequency

420 kHz @ Cx = 0 pF

Accuracy

deviation <0.1% of actual measurement value

Non-linearity

0.1% full scale

Repeatability

0.1% actual measurement

Temperature stability

0.15 pF (0pF) or <0.25% (typically <0.1%) of actual

 

measurement value, whichever is greater over the full

 

temperature range of the transmitter