Siemens Sitrans Process Conditions, Approvals, Specifications, Lloyds Register of Shipping

Models: Sitrans

1 122
Download 122 pages 51.76 Kb
Page 13
Image 13
Process Conditions

Process Conditions

Pressure rating1

 

standard

FV (full vacuum) to 200 bar (2920 psi)

option

up to 525 bar (7665 psi)

Temperature rating1

 

standard

–200 °C to 200 °C (–328 °F to 392 °F)

option

up to 400 °C (752 °F)

Approvals

CE

Complies with the requirements of E.C.C. as per EN 55011

 

and EN 61326

 

Dust Ignition Proof (DIP)

ATEX II 3GD (EEx nA [ib] IIC T4...T6)

 

FM/CSA:

Class I, Div. 2, Gr. A,B,C,D T4

 

 

Class II, Div. 1, Gr. E,F,G T4

 

 

Class III, Div. 1, Gr. E,F,G T4

Intrinsically Safe (IS)

ATEX II 1 G (EEx ia IIC T4...T6)

 

FM/CSA:

Class I, Div. 1, Gr. A,B,C,D T4

Flame-proof/

ATEX II 1/2 GD (EEx d [ia] IIC T6...T1)

Explosion-proof enclosure

FM/CSA:

Class I, Div. 1, Gr. A,B,C,D T4

Sanitary

3A

 

Lloyds Register of Shipping

Categories ENV1, ENV2, ENV3, ENV5

European Pressure, PED

97 / 23 / EC

 

Note: See Appendix F: Approvals on page 96 for details of certification.

1.Please refer to page 18, Temperature/ Pressure Curve chart, for specific combi- nations of temperature and pressure.

7ML19985GE01

SITRANS LC 500 – INSTRUCTION MANUAL

Page 7

Specifications

Page 13
Image 13
Siemens Sitrans, LC 500 Process Conditions, Approvals, Specifications, Lloyds Register of Shipping, 97 / 23 / EC