Siemens LC 500, Sitrans instruction manual Rotary Switch Positions - Quick Reference

Models: Sitrans

1 122
Download 122 pages 51.76 Kb
Page 120
Image 120
Manual background

Units

NO KEYS Value read-out

Up Key- RED (+)

Down

Key-

BLUE (–)

Both

Keys

Default

Units

NO KEYS Value read-out

Up Key- RED (+)

Down

Key-

BLUE (–)

Both

Keys

Default

Rotary Switch Positions – Quick Reference

0

1

2

3

4

5

6

7

8

9

A

B

C

D

E

F

 

 

 

 

 

 

Menu LEVEL 0 (00 to OF)

 

 

 

 

 

 

 

PV Units

Num.

PV Units

Seconds

Seconds

%

%

mA

mA

Numeri-

Numeri-

PV Units

PV Units

PV Units

PV Units

PV Units

 

Selection

cal

cal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PV Value

Show

Highest/

Activation

De-Activation

Upper Thresh-

Lower Thresh-

Loop Current

Fault signal

Actual

Damping

LOWER limit

UPPER limit

Delta Value

LRV Value

URV Value

or

select PV

Lowest

Time Delay

Time Delay

old

old

 

 

Step

Value

PV

PV

PV

PV

PV

 

variable

PV

Current sig-

Current signal

Activation

De-Activation

in mA

22 or 3.6 mA

Size

 

 

 

for 4 c.q.

for 4 mA

for 20 mA

Fault

 

Memory

nal

 

Current signal

Current signal

 

 

 

 

 

 

20 mA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Set

Step TV0 to

Highest

Increase

Increase

Increase

Increase

Set Covered:

Set FAULT:

Increase

Increase

Increase

Increase

Increase

Increase

Increase

Menu

TVmax

PV Memory

 

 

Upper

Lower

 

 

Step Size

Damping

PV

PV

PV

PV

PV

Level

 

Read-out

Delay Time

Delay Time

Threshold

Threshold

20 mA (Hi)

 

to 10000

Value

LOWER limit

UPPER limit

Delta

LRV

URV

00 to 0F

 

 

 

 

Point

Point

 

22 mA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Set

Step TVmax

Lowest

Decrease

Decrease

Decrease

Decrease

Set Covered:

Set FAULT:

Decrease

Decrease

Decrease

Decrease

Decrease

Decrease

Decrease

Menu

to TV0

PV Memory

 

 

Upper Thresh-

Lower Thresh-

 

 

Step Size

Damping

PV

PV

PV

PV

PV

Level

 

Read-out

Delay Time

Delay Time

old

old Point

4 mA (Lo)

 

to 0.01

Value

LOWER limit

UPPER limit

Delta

LRV

URV

10 to 1F

 

 

 

 

Point

 

 

3.6 mA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Show-

Set

Reset Hi/Lo

Toggle

Toggle

Preset Upper

Preset Lower

Set Analog

Fault signal

Set to 1

Set to 1

Preset

Preset Upper

URV– LRV

LRV = Actual

URV =

Menu

% Mode

memories to

Delay Time

Delay Time

Threshold

Threshold

Range

 

 

 

Lower Limit to

Limit to

= Min.

Value (PV)

Actual

Level

 

actual PV

00 < – > 100

00 < – > 100

Point to 75%

Point to 25%

4 to 20 mA (Anl)

Disable

 

 

Actual (PV)

Actual (PV)

 

 

Value (PV)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*

TVO

*

00

00

75%

25%

Analog

Disabled

1.0

1

1.666 pF

3300 pF

3300 pF

0 pF

3300 pF

 

 

 

 

 

 

Menu LEVEL 1 (10 to 1F)

 

 

 

 

 

 

 

PV Units

Numerical

Factory

Seconds

Seconds

%

%

O/ C

O/C

nor / inv

 

 

Resp. Units

 

 

Keylock

 

 

Settings

 

 

 

 

 

 

 

 

 

 

 

 

 

PV Value

Display

FAC

Activation

De-Activation

Upper Thresh-

Lower Thresh-

Status

Fault signal

MODE

Transmitter

Keylock

or

check

(factory set-

Time Delay

Time Delay

old Activation

old De-Activa-

Solid-state

(Solid-state

Normal /

Spare

Spare

Var 0

Spare

Spare

Level

Fault

 

tings)

Transistor

Transistor

Transistor

tion Transistor

Output

Output)

Inverse

 

 

Read-Out

 

 

 

 

Fault code

 

Switch

Switch)

Switch

Switch

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Set Menu

 

FAC

Increase

Increase

Increase

Increase

Set Covered =

Set FAULT =

MODE

 

 

Transmitter

 

 

Increase

Level

 

(factory set-

 

 

Upper Thresh-

Lower Thresh-

 

 

Normal /

 

 

Var 1

 

 

Keylock

00 to 0F

 

tings)

Delay Time

Delay Time

old Point

old Point

Solid-state ON

Solid-state ON

Inverse

 

 

Read-Out

 

 

Level

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Set Menu

 

FAC

Decrease

Decrease

Decrease

Decrease

Set Covered =

Set FAULT =

MODE

 

 

Transmitter

 

 

Decrease

Level

 

(factory set-

 

 

Upper Thresh-

Lower Thresh-

 

 

Normal /

 

 

Var 2

 

 

Keylock

10 to 1F

 

tings)

Delay Time

Delay Time

old Point

old Point

Solid-state OFF

Solid-state OFF

Inverse

 

 

Read-Out

 

 

Level

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Show

Invert Sig-

do it

Toggle Delay

Toggle Delay

Preset Upper

Preset Lower

Disable Switch

Disable Fault

Toggle

 

 

Transmitter

 

 

 

Menu

nalling Sta-

 

Time

Time

Threshold

Threshold

for Solid-state

for Solid-state

Operating

 

 

Var 3

 

 

 

Level

tus

 

00 < - > 100

00 < - > 100

Point to 75%

Point to 25%

 

 

Mode

 

 

Read-Out

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*

*

*

00

00

75%

25%

Disabled

Disabled

nor

*

*

*

*

*

0

Page 120
Image 120
Siemens LC 500, Sitrans instruction manual Rotary Switch Positions - Quick Reference