Output Signal Processing Test

Displays the Fault/Failure information. If operation is normal, two test displays alternate, which light up all the LCD segments in a cycle. If there is a fault or failure, an error code is displayed. See the detailed list of error codes and their meanings, page 53.

Menu

Rotary

 

 

Switch

Left Arrow

Description

Item

Position

 

 

 

 

 

11

1

On

Output Signal Processing Test

 

 

 

 

Set the rotary switch to 1.

To change the state of the output signals, press and hold both buttons simultaneously: the digital mode outputs (the solid-state switch and the loop-current control in digital mode) change to their opposite state. Thus 4mA becomes 20mA and contact open becomes contact closed. This feature allows you to verify that the output signals are properly processed further on in the PLC/DCS system: if the normal state is non-alarm, changing the state should generate an alarm.

The outputs stay in the opposite state as long as both buttons are pressed.

Factory Settings

Displays whether the factory settings are still in place, or how much they have been changed, and allows you to restore the factory settings.

Menu

Rotary

 

 

LCD

 

Item

Switch

Left Arrow

Description

Display

Meaning

 

Position

 

 

 

 

 

 

 

 

 

No parameters

 

 

 

Factory Settings

FAC A

changed from factory

 

 

 

 

 

setting

 

 

 

 

 

 

12

2

On

 

 

Range settings altered:

 

FAC P

timers and thresholds

 

 

 

 

 

 

 

 

 

unchanged

 

 

 

 

 

 

 

 

 

 

FAC ?

More parameters have

 

 

 

 

been changed

 

 

 

 

 

 

 

 

 

 

 

Set the rotary switch to 2. To restore the factory settings, press both buttons simultaneously to change the LCD to ‘do it’ and hold both buttons for more than one second. When the buttons are released, the LCD displays FAC A.