Siemens LC 500 Interface Version, Appendix E, Process Connection Size, Options, Conduit Entry

Models: Sitrans

1 122
Download 122 pages 51.76 Kb
Page 94
Image 94
Interface Version

Interface Version

Designed specifically for interface level where a long distance active shield portion of the electrode is required (up to 35 meters) before the measurement portion of the electrode begins. Common in large storage tanks for oil where the bottom of the tank invariably has a layer of water below the oil. Often, when measurement spans as much as 5.5 meters (for the water), up to 35 meters of flexible bellows cable are used.

Interface Version, threaded (optional sanitary and flanged)

Appendix E

ø 160 mm (6.3”)

transmitter enclosure

seal gland

185 mm (7.28”)

process connection: flange or threaded mounting

flexible tube

insertion length 35 m (115 ft) max.

Active Shield

probe

 

ø16 mm=2 m

ø 16 mm (0.63”) or

ø24 mm=5.5 m

active

ø 24 mm (0.94”)

length

 

100 mm (3.9”)

 

inactive tip

 

 

 

 

 

 

adjustable

 

dependent on

 

 

 

 

extension length

 

 

 

extension

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Process Connection Size

threaded version: ¾", 1", 1½", 2" NPT, BSPT, or JIS

sanitary version: on customer request

flanged version: on customer request

Options

thermal isolator

stilling well

Aluminum Enclosure

NEMA 4 / Type 4 / IP65

Conduit Entry:

½" NPT (2x)

Page 88

SITRANS LC 500 – INSTRUCTION MANUAL

7ML19985GE01

Page 94
Image 94
Siemens LC 500, Sitrans Interface Version, Appendix E, Process Connection Size, Options, Aluminum Enclosure, Conduit Entry