Reconstructing Data Volume (Changing RAID Types) (Only the NSR-100/50)

RAID constructions that can be set as data volumes differ depending on the model number of the NSR.

* RAID is not available for the NSR-25.

Model

Type

Approximate

Redund-

Default

 

 

capacity

ancy

setting

 

 

 

 

 

NSR-100

RAID-5

670 GB

Yes

Yes

 

 

 

 

 

 

RAID-1+0

450 GB

Yes

 

 

 

 

 

 

 

RAID-0

900 GB

None

 

 

 

 

 

 

NSR-50

Spanning

430 GB

Partial

Yes

 

 

 

 

 

 

RAID-1

210 GB

Yes

 

 

 

 

 

 

Caution

Be aware that all settings information and recorded images are deleted when reconstructing data volume.

When changing the settings is necessary, make sure to change the RAID construction beforehand.

1 Connect the USB keyboard and USB mouse to the NSR, and turn on the power.

The following screen and a progress bar for hardware startup appear.

2 Press F12 on the keyboard while the progress bar is displayed.

The screen similar to the following appears.

Example: For the NSR-50 (there are 3 menu items for the NSR-100)

*The number of devices and their names may differ from the following example screen.

Boot Menu

1.QSI DVD+/–RW SDW-0826

2.WDC WD2500JD-22HBC0-(S1)

3.WDC WD2500JD-22HBC0-(S2)

4.PQI IDE DiskOnModule-(SM)

<Enter Setup>

Chapter 2 Initial Configuring the System

36