6.Network Environment

It is required to follow the recommendation of the environment where THE CAMERA will be

installed or the similar environment.

6-1. Private line Environment

Usually Company, University, Research center use the leased line. They use many public IP addresses. In order to install THE CAMERA under this environment, select “Static IP Address” in ‘Static IP Setting’ of ‘3. Basic Setting’ and input IP address, subnet mask and gateway. If there is DHCP server on the network, select ‘Dynamic IP Address’ in ‘Dynamic IP’ of ‘3. Basic Setting’. You can get all the information (IP address, subnet mask, gateway, DHCP server) from the network administrator. Sometimes, the THE CAMERA may not work properly if the user installed firewall for security purpose. In this case, open the port on the THE CAMERA, then it will work properly. You can check the current port of THE CAMERA from the “Administrator's Page”->”Network Setting”- >”Port Setting” (see ‘3. Basic Setting‘). The default port is set on ex-factory as follows :

￿

Web Connection Port

: Port 80 TCP

￿

Authentication and Control Port

: Port 9000 TCP

￿

Video Streaming Port

: Port 9001 TCP

￿

Motion Detectin Control Port

: Port 9005 TCP

6-2.Broadband (ADSL, Cable, Fiber Optic) Modem Environment

Home, store, small office use one Broadband modem (DSL, Cable Modem), and use one public IP address. In order to use several PC through one Public IP address, the user in most cases use IP sharing device. We recommend to use a IP router (IP Sharing device) to install the THE CAMERA. There may be a case in no need of router, but most people use THE CAMERA and other PC 1set or more. When using the router, connect the router and input IP address of THE CAMERA (IP address of THE CAMERA is set as 192.168.1.7 on ex-factory) in DMZ menu. If the user cannot use the DMZ function because there is no DMZ menu in the router or some other reasons, go into port forwarding or NAT menu on the router and map the port of THE CAMERA one by one. User can check the current port setting of THE CAMERA from “Administrator's Page”->”Network Setting”- >”Port Setting” (see ‘3. Basic Setting‘). Manufacturer’s setting of THE CAMERA is as follow on ex- factory : (The user can change port if necessary).

115

Page 115
Image 115
Speco Technologies & IP-WDRB1, IP-INTT5 user manual Network Environment