95
IP Camera Users Manual Speco Technologies
* Before activating Alarm, user must set ALARM ENABLE at DOME SET – ALARM –
ENABLE (Refer to page 15)
I. SECTOR SET
Up to 8 programmable sectors are available with 16 characters.
This feature is useful to memory the certain location such as parking zone or so on.
When camera goes through this area, it shows the letter you memorized.
I-1. SECTOR SET – SECTOR NO.
Up to 8 programmable sectors set by the five keys are available.
I-2. SECTOR SET – SECTOR ID
set SECTOR ID, select up to 16 characters by using five keys to the left or right.
Press ZOOM TELE button to move to the next character from the left to the right
direction and ZOOM WIDE button to move to the next character from the right to left
direction (Space displays when appears)
I-3. SECTOR SET – SECTOR START
To set SECTOR START angle, press FOCUS FAR button then move five keys to the
left or right direction to set the position. To press FOCUS FAR button again is to
escape.
SECTOR SET
SECTOR NO : 01
SECTOR ID : SECTOR01□□□□□□□□
SECTOR START: XXX.X.XX.X
SECTOR END : XXX.X.XX.X
SAVE
EXIT
DEFAULT SETTING
Start Position
End Position