H. ALARM SET
4 Alarm inputs are available and each alarm is activating to presets, group tours or
patterns.
|
| ALARM SET |
|
| |
|
|
|
| ||
ALARM NO |
| : 01 |
|
| |
ALARM INPUT: OFF | DEFAULT SETTING | ||||
ALARM ACT | : 001 |
|
| ||
SAVE |
|
|
| ||
EXIT |
|
|
|
H-1. ALARAM SET – ALARM NO.
Up to 4 alarms are selectable by using five keys to the right direction when cursor is on ALARM NO.
H-2. ALARAM SET – ALARM INPUT
Input alarm ways provide two different ways as NC (Normal Close) or NO (Normal
Close)
The default setting is OFF
H-3. ALARAM SET – ALARM ACT
Alarm activates various surveillance modes with Preset number up to 165, Group tour up to 8, Pattern up to 8. Move five keys to the right or left direction to select any preset number, group tour no. or pattern no.
H-4. ALARAM SET – SAVE
After setting the alarm input ways and activation, to save the data, move five keys to the right direction when the cursor is on SAVE. After saving the data, the cursor moves to Alarm NO.2 automatically to prepare the next alarm.
H-5. ALARAM SET – EXIT
To escape this page, move five keys to the right direction