250CHAPTER 15: T1-F INTERFACE CONFIGURATION COMMANDS

ft1 alarm-threshold

Syntax

ft1 alarm-threshold { ais { level-1 level-2 } lfa { level-1 level-2 level-3 level-4 }

 

los { pulse-detection pulse-recovery } value }

 

undo ft1 alarm-threshold

View

T1-F interface view

Parameter

ais: Sets the alarm threshold of alarm indication signal (AIS), which can be level-1

 

and level-2.

 

The level-1keyword specifies to generate an AIS alarm when the number of 0s

 

in the bit stream of an SF or ESF frame is less than or equal to 2.

 

The level-2keyword specifies to generate an AIS alarm when the number of 0s

 

is less than or equal to 3 in the bit stream of an SF frame or less than or equal

 

to 5 in the bit stream of an ESP frame.

 

By default, level-1 AIS alarm threshold applies.

 

lfa: Sets the loss of frame align (LFA) alarm threshold, which can be level-1,

 

level-2,level-3, and level-4.

 

The level-1keyword specifies to generate an LFA alarm when two of four

 

frame alignment bits are lost.

 

The level-2keyword specifies to generate an LFA alarm when two of five

 

frame alignment bits are lost.

 

The level-3keyword specifies to generate an LFA alarm when two of six frame

 

alignment bits are lost.

 

The level-4keyword applies only to ESF frames. It specifies to generate an LFA

 

alarm when errors are detected in four consecutive ESF frames.

 

By default, level-1 LFA alarm threshold applies.

 

los: Sets a loss of signal (LOS) alarm threshold, which can be pulse-detection(for

 

the pulse detection duration threshold with LOS) and pulse-recovery(for the

 

pulse threshold with LOS).

 

The threshold of pulse-detection, in units of pulse intervals, ranges from 16 to

 

4,096 and defaults to 176.

 

The threshold of pulse-recovery, ranges from 1 to 256 and defaults to 22.

 

If the number of the pulses detected during the total length of the specified pulse

 

detection intervals is smaller than the pulse-recovery threshold, a LOS alarm

 

occurs. For example, if the two thresholds take their defaults, a LOS alarm is

 

created if the number of pulses detected within 176 pulse intervals is less than 22.

Description

Use the ft1 alarm-thresholdcommand to set LOS, AIS, or LFA alarm thresholds

 

on the T1-F interface.

Page 250
Image 250
3Com MSR 30, MSR 50 manual Ft1 alarm-threshold, Undo ft1 alarm-threshold, On the T1-F interface