2593

Use the undo echo-cancellercommand to restore the default.

By default, the convergence rate of comfort noise amplitude is 0, the maximum amplitude of comfort noise is 256, the comfort noise mixture proportion control factor is 100, and the threshold of two-way talk is 1.

Related command: echo-canceller.

Example # Set the convergence rate of comfort noise amplitude to 50.

<Sysname> system-view [Sysname] voice-setup

[Sysname-voice] echo-canceller parameter convergence-rate 50

em-phy-parm

Syntax

em-phy-parm { 2-wire 4-wire }

 

undo em-phy-parm

View

Analog E&M voice subscriber line view

Parameter

2-wire: Chooses the 2-wire analog E&M wire scheme.

 

4-wire: Chooses the 4-wire analog E&M wire scheme.

Description

Use the em-phy-parmcommand to configure a wire scheme for the analog E&M

 

subscriber line.

 

Use the undo em-phy-parmcommand to restore the default.

 

By default, the 4-wire analog E&M cable is selected.

 

This command is only applicable only to the analog E&M subscriber line. The

 

configuration will apply to all E&M interfaces of the card after you configure this

 

command.

Example

# Choose the 4-wire scheme for the analog E&M subscriber line.

 

<Sysname> system-view

 

[Sysname] voice-setup

 

[Sysname-voice] subscriber-line 1/0

 

[Sysname-voice-line1/0] em-phy-parm 4-wire

em-signal

Syntax em-signal { delay immediate wink } undo em-signal

Page 2593
Image 2593