2281

Example # Configure the timeout time in a DHCP probe as 10000 milliseconds.

<Sysname> system-view [Sysname] nqa entry admin test [Sysname-nqa-admin-test] type dhcp

[Syaname-nqa-admin-test-dhcp] probe timeout 10000

reaction

Syntax reaction item-numchecked-element probe-fail threshold-type consecutive occurrences [ action-type { none trigger-only } ]

undo reaction item-num

View DHCP/DLSw/FTP/HTTP/ICMP-echo/SNMP/TCP/UDP-echo test type view

Parameter item-num: Number of the collaboration entry, in the range 1 to 10.

checked-element: Type of the monitored element in collaboration. At present, the type of the monitored element can be probe failure only.

probe-fail: The type of the monitored element is probe failure.

threshold-type consecutive: Threshold type is consecutive probe failures.

occurrences: Number of consecutive probe failures, in the range 1 to 16.

action-type: Triggered action type, defaulting to none.

none: No actions.

trigger-only: Triggers collaboration between other modules only.

Description Use the reaction command to establish a collaboration entry to monitor the probe results of the current test group. If the number of consecutive probe failures reaches the threshold, collaboration with other modules is triggered.

Use the undo reaction command to remove the collaboration entry.

By default, no collaboration entries are configured.

Note that you cannot modify the content of a collaboration object using the reaction command after the collaboration object is created.

Related command: “track” on page 2529.

Example # Create collaboration object 1. If the number of consecutive probe failures reaches 3, collaboration with other modules is triggered.

<Sysname> system-view

[Sysname] nqa entry admin test

[Sysname-nqa-admin-test] type tcp

Page 2281
Image 2281
3Com MSR 50, MSR 30 manual Reaction, 2281