2223

standby timer flow-check

Syntax standby timer flow-check interval

undo standby timer flow-check

View Interface view

Parameter interval: Specifies flow check interval, in the range 30 to 600 seconds.

Description Use the standby timer flow-checkcommand to configure the interval for checking the traffic size on the main interface.

Use the undo standby timer flow-checkcommand to restore the default.

By default, the interval for checking the traffic size on the main interface is 30 seconds.

Note that this command can be executed after backup interfaces are specified.

Related command: standby interface.

Example # Configure load sharing, backup bandwidth and flow check interval on interface Serial 2/0 to 60 seconds.

<Sysname> system-view

[Sysname] interface serial 2/0

[Sysname-Serial2/0] standby timer flow-check 60

standby track

Syntax standby track track-entry-number

undo standby track

View Interface view

Parameters track-entry-number: Specifies a Track object to be monitored by its number, in the range 1 to 1024.

Description Use the standby track command to configure the association between an interface and a Track object.

Use the undo standby track command to remove the association.

By default, an interface is not associated with a Track object.

Note that:

Page 2223
Image 2223
3Com MSR 50, MSR 30 manual Standby timer flow-check, Standby track, Undo standby track, 2223