204CHAPTER 12: FUNDAMENTAL CE1/PRI INTERFACE CONFIGURATION COMMANDS

crc

Syntax

crc { 16 32 none }

 

undo crc

View

Synchronous serial interface view

Parameter

16: Adopts 16-bit cyclic redundancy check (CRC).

 

32: Adopts 32-bit CRC.

 

none: Disables CRC.

Description

Use the crc command to configure CRC mode for a synchronous serial interface

 

formed on a CE1/PRI interface.

 

Use the undo crc command to restore the default, that is, 16-bit CRC.

Example

# Apply 32-bit CRC to a serial interface formed on interface CE1 interface 2/0 in

 

unchannelized mode.

 

<Sysname> system-view

 

[Sysname] controller e1 2/0

 

[Sysname-E1 2/0] using e1

 

[Sysname-E1 2/0] quit

 

[Sysname] interface serial 2/0:0

 

[Sysname-Serial2/0:0] crc 32

detect-ais

Syntax detect-ais

undo detect-ais

View CE1 interface view, PRI interface view

Parameter None

Description Use the detect-aiscommand to enable AIS (alarm indication signal) test on an interface.

Use the undo detect-aiscommand to disable AIS test.

By default, AIS test is performed.

Example # Enable AIS test on E1 2/0 interface.

Page 204
Image 204
3Com MSR 30, MSR 50 manual Detect-ais, Crc 16 32 none, Syntax detect-ais Undo detect-ais