2669

 

undo special-character character number

View

R2 CAS view

Parameter

character: Special character, which can be a pound sign (#) or asterisk (*), A, B, C,

 

or D.

 

number: Code of register signal, in the range 11 to 16.

Description

Use the special-charactercommand to configure the special characters

 

acceptable during register signal exchange.

 

Use the undo special-charactercommand to remove the configured special

 

characters.

 

By default, no special characters are configured.

 

This command applies to R2 signaling only.

 

You may need to configure this command to accommodate to some national R2

 

signaling variants where Group I forward signals can represent special characters

 

such as pound signs (#) and asterisks (*) in addition to digits.

n

You cannot use the special-charactercommand to assign a special character

different signal values.

 

To ensure that the device can process calls correctly, assign special characters

 

different signal values.

Example

# Assign the pound sign (#) the register signal code 11.

 

<Sysname> system-view

 

[Sysname] controller e1 1/0

 

[Sysname-e1 1/0] timeslot-set 0 timeslot-list 1-31 signal r2

 

[Sysname-e1 1/0] cas 0

 

[Sysname-cas1/0:0] special-character # 11

 

 

subscriber line

 

Syntax

subscriber line slot-number:{ts-set-number 15 23 }

View

Voice view

Parameter

slot-number: Number of the voice subscriber line automatically created upon

 

creation of a TS group or ISDN PRI set.

 

ts-set-number: Number of the TS group that has been created.

 

15: Indicates the subscriber line is created for the ISDN PRI set created on an E1

 

interface.

Page 2669
Image 2669
3Com MSR 50, MSR 30 manual Undo special-character character number, Different signal values