ATM OC-3C/STM-1 INTERFACE

4 CONFIGURATION COMMANDS

clock

Syntax

clock { master slave }

 

undo clock

View

ATM OC-3c interface view, STM-1 interface view

Parameter

master: Sets the clock mode as master.

 

slave: Sets the clock mode as slave.

Description

Use the clock command to set the clock mode for an ATM OC-3c/STM-1

 

interface.

 

Use the undo clock command to restore the default, that is, the slave clock

 

mode.

 

When the ATM interface is operating as DCE, set its clock mode to master. When

 

the interface is operating as DTE, set its clock mode to slave.

 

When the ATM interfaces on two routers are connected directly through a

 

fiber-optic cable, set the clock mode to master at one end and to slave at the other

 

end.

Example

# Set the clock mode of ATM interface 5/0 to master.

 

<Sysname> system-view

 

[Sysname] interface atm 5/0

 

[Sysname-Atm5/0] clock master

frame-format

Syntax

frame-format { sdh sonet }

 

undo frame-format

View

ATM OC-3c interface view, STM-1 interface view

Parameter

sdh: Sets the framing format to SDH STM-1, the synchronous transport

 

module-level 1 (STM-1) of synchronous digital hierarchy (SDH).

Page 127
Image 127
3Com MSR 50, MSR 30 manual Frame-format sdh sonet