You may view the state and result of the BERT test with the display controller t1 command.

Example # Run a 10-minute 2^20 BERT test on CT1/PRI interface t1 2/0.

<Sysname> system-view

[Sysname] controller t1 2/0

[Sysname-T1 2/0] bert pattern 2^20 time 10

cable (CT1/PRI interface view)

Syntax

cable { long { 0db -7.5db -15db -22.5db } short { 133ft 266ft 399ft 533ft

 

655ft } }

 

undo cable

View

CT1/PRI interface view

Parameter

long: Matches 199.6-meter (655-feet) and longer cable length. The options for

 

this parameter include 0db, -7.5db, -15dband -22.5db. The attenuation

 

parameter is selected depending on the signal quality received at the receiving

 

end. In this case, no external CSU is needed.

 

short: Matches a cable length shorter than 199.6 meters (655 feet). The options

 

for this parameter include 133ft, 266ft, 399ft, 533ft and 655ft. The length

 

parameter is selected depending on the actual transmission distance.

Description

Use the cable command to set the cable attenuation and length on the CT1/PRI

 

interface.

 

Use the undo cable command to restore the default, that is, long 0db.

 

You may use this command to adapt signal waveform to different transmission

 

conditions such as the quality of the signal received by the receiver. If the signal

 

quality is good, you can use the default setting. In this case, the CT1/PRI interface

 

does not need an external CSU device.

Example

# Set the cable length to 40.5 meter (133 feet) on CT1/PRI interface T1 2/0.

 

<Sysname> system-view

 

[Sysname] controller t1 2/0

 

[Sysname-T1 2/0] cable short 133ft

channel-set (CT1/PRI interface view)

Syntax channel-set set-numbertimeslot-list list [ speed { 56k 64k } ]

undo channel-set [ set-number]

View CT1/PRI interface view