358 CHAPTER 21: BASIC DLSW CONFIGURATION COMMANDS
llc2 timer reject
Syntax llc2 timer reject mseconds
undo llc2 timer reject
View Ethernet interface view
Parameter mseconds: LLC2 REJ status time in milliseconds. The effective range is 1 to 60,000.
Description Use the llc2 timer reject command to configure the LLC2 REJ status time,
namely the amount of time the router waits for the expected frame after it
receives an unexpected frame and sends a reject frame.
Use the undo llc2 timer reject command to restore the default setting.
By default, the LLC2 REJ status time is 500 milliseconds.
Example # Set the LLC2 REJ time to 2, 000 milliseconds on Ethernet 1/0.
<Sysname> system-view
[Sysname] interface ethernet 1/0
[Sysname-Ethernet1/0] llc2 timer reject 2000
reset dlsw circuits
Syntax reset dlsw circu its [ circuit-id ]
View User view
Parameter circuit-id: DLSw virtual circuit ID, in the range of 0 to 0xFFFFFFFF.
Description Use the reset dlsw circuits command to clear DLSw virtual circuit information.
Note that this command without circuit-id clears the information of all DLSw
virtual circuits; otherwise, this command clears the information of the specified
virtual circuit.
Example # Clear the information of virtual circuit 100.
<Sysname> reset dlsw circuits 100
reset dlsw reachable-cache
Syntax reset dlsw reachable-cache
View User view