2258 CHAPTER 148: DEVICE MANAGEMENT COMMANDS

<Sysname> display

power

Power

1

State:

Absent

Power

2

State:

Normal

Power

3

State:

Absent

The above information indicates that power supply 2 works normally, and power supply 1 and power supply 3 are absent.

display reboot-type

Syntax

display reboot-type [ slot slot-number]

View

Any view

Parameter

slot slot-number: Displays reboot type of the specified card, where slot-number

 

represents the slot number of a card. The value range varies with devices.

Description

Use the display reboot-typecommand to display the reboot type of a device.

Example

# Display the reboot type of the card in slot 2 of the device.

 

<Sysname> display reboot-type slot 2

 

The rebooting type this time is: Cold

 

The above information indicates that the last reboot type of the device is Cold

 

boot. (If it is displayed as Warm, it indicates the reboot type is ware boot).

display schedule reboot

Syntax

display schedule reboot

View

Any view

Parameter

None

Description

Use the display schedule reboot command to display the device reboot time

 

set by the user.

Related command:

schedule reboot at and schedule reboot delay.

Example

# Display the reboot time of a device.

 

<Sysname> display schedule reboot

 

System will reboot at 16:00:00 2006/03/10 (in 2 hours and 5 minutes).

The above information indicates the system will reboot at 16:00:00 on March 10, 2006 (in two hours and five minutes).

Page 2258
Image 2258
3Com MSR 30, MSR 50 manual Display schedule reboot, Display reboot-type slot slot-number