917

terminal-number: Terminal number, ranging 1 to 255.

Description Use the rta terminal command to apply a template on the interface.

Use the undo rta terminal command to cancel the template application.

By default, no template is applied on the interface.

A terminal can be created only after the configured template is applied on the corresponding interface, so as to implement terminal access. Use the terminal-numberargument to specify the terminal number. An interface can be connected to only one physical terminal. The router identifies physical terminals by terminal number.

Note that at least one VTY should be configured in the terminal template for the template to be applied on the interface. This command supports asynchronous serial interfaces, synchronous/asynchronous serial interfaces, and AUX interfaces. This command can be configured on a synchronous/asynchronous serial interface only when the interface operates in the asynchronous mode.

Example # Apply the terminal template abc with the terminal number of 1 on the interface.

<Sysname> system-view

[Sysname] interface async 1/1

[Sysname-rta-async1/1] rta terminal abc 1

sendbuf bufsize

Syntax sendbuf bufsize size

undo sendbuf bufsize

View Terminal template view

Parameters size: Maximum size of data sent to the terminal at one time, in bytes, ranging 2 to 500.

Description Use the sendbuf bufsize command to configure the maximum size of data to be sent to the terminal.

Use the undo sendbuf bufsize command to restore the default.

By default, the maximum size of data to be sent to the terminal at one time is 500 byes.

The router sends data in packets to the terminal. The sizes of the sent packets are different. Use the size argument to specify the maximum data packet size.

Example # Configure the maximum size of data to be sent at one time as 200 bytes.

Page 917
Image 917
3Com MSR 50, MSR 30 manual Sendbuf bufsize, Syntax sendbuf bufsize size Undo sendbuf bufsize, 917