1612 CHAPTER 96: MPLS TE CONFIGURATION COMMANDS

View Interface view

Parameter None

Description Use the mpls rsvp-te srefresh command to enable summary refresh.

Use the undo mpls rsvp-te srefresh command to restore the default.

By default, summary refresh is disabled.

Summary refresh (Srefresh) messages refresh path state and reservation state.

Enabling summary refresh disables conventional time-driven state refresh.

Example # Enable summary refresh on interface Ethernet 1/0.

<Sysname> system-view

[Sysname] interface ethernet 1/0

[Sysname-Ethernet1/0] mpls rsvp-te srefresh

mpls rsvp-te timer graceful-restart recovery

Syntax mpls rsvp-te timer graceful-restart recovery recovery-time

undo mpls rsvp-te timer graceful-restart recovery

View MPLS view

Parameters recovery-time: RSVP-TE GR recovery interval in seconds, in the range 60 to 300.

Description Use the mpls rsvp-te timer graceful-restart recovery command to set the RSVP-TE GR recovery interval.

Use the undo mpls rsvp-te timer graceful-restart recovery command to restore the default.

By default, the RSVP-TE GR recovery interval is 300 seconds.

Examples # Set the RSVP-TE GR recovery interval to 100 seconds.

<Sysname> system-view [Sysname] mpls

[Sysname-mpls] mpls rsvp-te timer graceful-restart recovery 100

mpls rsvp-te timer graceful-restart restart

Syntax mpls rsvp-te timer graceful-restart restart restart-time

undo mpls rsvp-te timer graceful-restart restart

View MPLS view