TERMINAL ACCESS CONFIGURATION

70 COMMANDS

auto-close

Syntax auto-close time

undo auto-close

View Terminal template view

Parameters time: Automatic link teardown time, in seconds. It ranges from 5 to 240.

Description Use the auto-closecommand to configure the automatic link teardown time.

Use the undo auto-closecommand to restore the default. By default; the automatic link teardown time is 0 seconds, namely, no automatic link teardown is performed.

The terminal access feature supports the automatic link teardown function. You can enable the function and configure the teardown time in terminal template view. With this function enabled, if a terminal is disconnected from the router, the terminal enters the state of DOWN, and the router will automatically tear down the TCP connection to the front-end processor (FEP) after the specified time period. If the function is disabled, the TCP connection will always remain.

Example # Set the automatic link teardown time to 10 seconds.

<Sysname> system-view

[Sysname] rta template abc

[Sysname-rta-template-abc] auto-close 10

auto-link

Syntax auto-link time

undo auto-link

View Terminal template view

Parameters time: Automatic link establishment time, in seconds. It ranges from 5 to 240.

Description Use the auto-linkcommand to configure the automatic link establishment time.

Page 899
Image 899
3Com MSR 50, MSR 30 Terminal Access Configuration Commands, Auto-close, Auto-link, Syntax auto-close time Undo auto-close