2622 CHAPTER 173: VOIP CONFIGURATION COMMANDS

Description Use the voip timer command to set the duration for switching from a VoIP entity to a backup POTS entity after a VoIP call failure.

Use the undo voip timer command to restore the default.

By default, the duration for switching from a VoIP entity to a backup POTS entity after a call failure is 5 seconds.

Example # Configure the duration for switching from a VoIP entity to a backup POTS entity after a call failure to 3 seconds.

<Sysname> system-view

[Sysname] voice-setup

[Sysname-voice] voip timer voip-to-pots 3

vqa dscp

Syntax vqa dscp { media signal } dscp-value

 

undo vqa dscp { media signal }

 

View

Voice view

 

 

Parameter

media: Global DSCP value in the ToS field of the IP packets that carry RTP streams.

 

signal: Global DSCP value in the ToS field of the IP packets that carry voice

 

signaling.

 

 

 

dscp-value: DSCP value in the range 0 to 63 or the keyword af11, af12, af13,

 

af21, af22, af23, af31, af32, af33, af41, af42, af43, cs1, cs2, cs3, cs4, cs5, cs6,

 

cs7, or ef.

 

 

 

Table 684

DSCP values

 

 

 

 

 

 

Keyword

DSCP value in binary

DSCP value in decimal

 

 

 

 

 

af11

001010

10

 

af12

001100

12

 

af13

001110

14

 

af21

010010

18

 

af22

010100

20

 

af23

010110

22

 

af31

011010

26

 

af32

011100

28

 

af33

011110

30

 

af41

100010

34

 

af42

100100

36

 

af43

100110

38

 

cs1

001000

8

 

cs2

010000

16

Page 2622