POS INTERFACE CONFIGURATION

7 COMMANDS

clock

Syntax

clock { master slave }

 

undo clock

View

POS interface view

Parameter

master: Sets the clock mode of the POS interface to master.

 

slave: Sets the clock mode of the POS interface to slave.

Description

Use the clock command to set the clock mode of the POS interface.

 

Use the undo clock command to restore the default, that is, slave.

 

POS interfaces support two clock modes:

 

Master, which uses internal clock signal.

 

Slave, which uses line clock signal.

 

Similar to the DTE/DCE model of synchronous serial interfaces, POS interfaces

 

need to choose a clock mode. When a POS interface on the router is directly

 

connected to another router, the only requirement is that the two sides use

 

different clock modes. In connection to a switch, however, the switch is DCE and

 

uses internal clock, so the POS interface is DTE and must adopt the slave clock

 

mode.

Example

# Set the clock mode of interface POS 1/0 to master.

 

<Sysname> system-view

 

[Sysname] interface pos 1/0

 

[Sysname-Pos1/0] clock master

crc

Syntax crc { 16 32 }

undo crc

View POS interface view

Page 151
Image 151
3Com MSR 50, MSR 30 manual POS Interface Configuration Commands, Crc, Syntax crc 16 Undo crc