225

<Sysname> system-view

[Sysname] controller t1 2/0

[Sysname-T1 2/0] fdl att

frame-format (CT1/PRI interface view)

Syntax

frame-format { esf sf }

 

undo frame-format

View

CT1/PRI interface view

Parameter

sf: Sets the framing format to super frame (SF).

 

esf: Sets the framing format to extended super frame (ESF).

Description

Use the frame-formatcommand to set the framing format on the CT1/PRI

 

interface.

 

Use the undo frame-formatcommand to restore the default, that is, esf.

 

CT1/PRI interfaces support two framing formats, that is, SF and ESF. In SF format,

 

multiple frames can share the same FSC and signaling information, so that more

 

significant bits are available for transmitting user data. The use of ESF allows you

 

to test the system without affecting the ongoing service.

Example

# Set the framing format of interface T1 2/0 to SF.

 

<Sysname> system-view

 

[Sysname] controller t1 2/0

 

[Sysname-T1 2/0] frame-format sf

idlecode (CT1/PRI interface view)

Syntax

idlecode { 7e ff }

 

undo idlecode

View

CT1/PRI interface view

Parameter

7e: Sets the line idle code to 0x7E.

 

ff: Sets the line idle code to 0xFF.

Description

Use the idlecode command to set the line idle code on the CT1/PRI interface.

 

Two types of line idle code are available: 0x7E and 0xFF.

 

Use the undo idlecode command to restore the default, that is, 0x7E.

Page 225
Image 225
3Com MSR 50, MSR 30 manual Frame-format CT1/PRI interface view, Idlecode CT1/PRI interface view, Frame-format esf sf