196CHAPTER 11: FUNDAMENTAL SERIAL INTERFACE CONFIGURATION COMMANDS

Description Use the invert receive-clockcommand to invert the receive-clock signal on the DTE-side synchronous serial interface.

Use the undo invert transmit-clockcommand to restore the default.

By default, receive-clock signal inversion is disabled on DTE-side synchronous serial interfaces.

Sometimes, you may need to invert the receive-clock signal on a DTE-side serial interface to eliminate the half clock-period delay on the line. This command is necessary only for some special DCE devices. In common applications, clock must not be inverted.

Related command: physical-mode,invert transmit-clock,clock (serial interface view).

Example # Invert the receive-clock on DTE-side synchronous serial interface 2/0.

<Sysname> system-view

[Sysname] interface serial 2/0

[Sysname-Serial1/0] invert receive-clock

invert transmit-clock

Syntax invert transmit-clock

undo invert transmit-clock

View Serial interface view

Parameter None

Description Use the invert transmit-clockcommand to invert the transmit-clock signal on the DTE-side synchronous serial interface.

Use the undo invert transmit-clockcommand to restore the default.

By default, transmit-clock signal inversion is disabled on DTE-side synchronous serial interfaces.

Sometimes, you may need to invert the receive-clock signal on a DTE-side serial interface to eliminate the half clock-period delay on the line. This command is necessary only for some special DCE devices. In common applications, clock must not be inverted.

Related command: physical-mode,invert receive-clock,clock (serial interface view).

Example # Invert the transmit-clock on DTE-side synchronous serial interface 2/0.

<Sysname> system-view

[Sysname] interface serial 2/0

[Sysname-Serial1/0] invert transmit-clock

Page 196
Image 196
3Com MSR 30, MSR 50 manual Invert transmit-clock, Syntax invert transmit-clock Undo invert transmit-clock