210CHAPTER 12: FUNDAMENTAL CE1/PRI INTERFACE CONFIGURATION COMMANDS

loopback (CE1/PRI interface view)

Syntax

loopback { local payload remote }

 

undo loopback

View

CE1/PRI interface view

Parameter

local: Sets the interface in local loopback mode.

 

remote: Sets the interface in external loopback mode.

 

payload: Sets the interface in external payload loopback mode.

Description

Use the loopback command to enable loopback and set the loopback mode.

 

Use the undo loopback command to restore the default.

 

By default, loopback is disabled.

 

Loopback is intended for checking the condition of interfaces or cables. Disable it

 

otherwise.

 

You can bundle timeslots on the CE1/PRI interface to form a serial interface and

 

encapsulate it with PPP. After you enable loopback on this serial interface, it is

 

normal that the state of the link layer protocol is reported down.

Example

# Set interface E1 2/0 in internal loopback mode.

 

<Sysname> system-view

 

[Sysname] controller e1 2/0

 

[Sysname-E1 2/0] loopback local

pri-set (CE1/PRI interface view)

Syntax

pri-set [ timeslot-list list ]

 

undo pri-set

View

CE1/PRI interface view

Parameter

timeslot-listlist: Specifies timeslots to be bundled. The list argument is timeslot

 

numbers, in the range of 1 to 31. You may specify a single timeslot by specifying a

 

number, a range of timeslots by specifying a range in the form of

 

number1-number2, or several discrete timeslots by specifying number1,

 

number2-number3.

Description

Use the pri-setcommand to bundle timeslots on the CE1/PRI interface into a PRI

 

set.

Page 210
Image 210
3Com MSR 30 Loopback CE1/PRI interface view, Pri-set CE1/PRI interface view, Loopback local payload remote, Undo pri-set