355

Parameter length: The maximum number of consecutive information frames the router can send before receiving an acknowledgment from the peer, in the range of 1 to 127.

Description Use the llc2 receive-windowcommand to configure the maximum number of consecutive information frames the router can send before receiving an acknowledgment from the peer.

Use the undo llc2 receive-windowcommand to restore the default setting.

By default, the maximum number of consecutive information frames the router can send before receiving an acknowledgment from the peer is 7.

Example # Set the maximum number of consecutive information frames the router can send before receiving an acknowledgment from the peer to 10 on Ethernet 1/0.

<Sysname> system-view

[Sysname] interface ethernet 1/0

[Sysname-Ethernet1/0] llc2 receive-window 10

llc2 timer ack

Syntax llc2 timer ack mseconds

undo llc2 timer ack

View Ethernet interface view

Parameter mseconds: LLC2 acknowledgment waiting time in milliseconds. The effective range is 1 to 60,000.

Description Use the llc2 timer ack command to configure the LLC2 acknowledgment waiting time, namely the maximum length of time the router waits for an acknowledgment from the peer after sending an LLC2 frame.

Use the undo llc2 timer ack command to restore the default setting.

By default, the LLC2 acknowledgment waiting time is 200 milliseconds.

Example # Set the LLC2 acknowledgment waiting time to 10 milliseconds on Ethernet 1/0.

<Sysname> system-view

[Sysname] interface ethernet 1/0

[Sysname-Ethernet1/0] llc2 timer ack 10

llc2 timer ack-delay

Syntax llc2 timer ack-delay mseconds

undo llc2 timer ack-delay

Page 355
Image 355
3Com MSR 50, MSR 30 manual Llc2 timer ack-delay, Syntax llc2 timer ack mseconds Undo llc2 timer ack, 355