228CHAPTER 13: FUNDAMENTAL CT1/PRI INTERFACE CONFIGURATION COMMANDS

When creating a PRI set on a CT1/PRI interface, note that timeslot 24 is the D channel for transmitting signaling; it cannot form a bundle that includes itself only. The attempts to bundle only timeslot 24 will fail.

In the created PRI set, timeslot 24 is used as D channel for signaling transmission, and the other timeslots as B channels for data transmission. You may randomly bundle these timeslots into a PRI set (as the D channel, timeslot 24 is automatically bundled). If no timeslot is specified, all timeslots are bundled into an interface similar to an ISDN PRI interface in the form of 23B+D.

For the PRI set, the system automatically creates a serial interface logically equivalent to an ISDN PRI interface. The serial interface is named in the form of serial number:23, where number is the number of the CT1/PRI interface on which the serial interface is created.

Because a channel set and a PRI set cannot coexist on a CT1/PRI interface, your PRI set creation attempt will fail if the channel-setcommand is configured.

Example # Bundle timeslots 1, 2, and 8 through 12 into a PRI set on CT1/PRI interface T1 2/0.

<Sysname> system-view

[Sysname] controller t1 2/0

[Sysname-T1 2/0] pri-set timeslot-list 1,2,8-12

reset counters controller t1

Syntax

reset counters controller t1 interface-number

View

User view

Parameter

interface-number: Interface number.

Description

Use the reset counters controller t1 command to clear the controller counter

 

for a CT1/PRI interface.

 

To display the value of the controller counter, use the display controller t1

 

command.

n

The reset counters interface command cannot clear the controller counters for

CT1/PRI interfaces. To do so, you must use the reset counters controller t1

 

command.

Example

# Clear the controller counter for CT1/PRI interface T1 2/0.

<Sysname> reset counters controller t1 2/0