3Com MSR 50, MSR 30 manual Rmon event

Models: MSR 50 MSR 30

1 2742
Download 2742 pages 31.98 Kb
Page 2323
Image 2323

2323

# Remove the alarm table entry with the index of 15.

<Sysname> system-view

[Sysname] undo rmon alarm 15

rmon event

Syntax

rmon event entry-number [ description string ] { log log-traplog-trapcommunity

 

none trap trap-community } [ owner text ]

 

undo rmon event entry-number

View

System view

Parameter

entry-number: Event entry index, in the range 1 to 65,535.

 

description string: Event description, a string of 1 to 127 characters.

 

log: Logs the event when it occurs.

 

log-traplog-trapcommunity: Log and trap events. The system records the log

 

information and sends a trap when the event occurs. log-trapcommunityindicates

 

the community name of the network management station that receives trap

 

messages, a string of 1 to 127 characters.

 

none: Performs no action when the event occurs.

 

trap trap-community: Trap event. The system sends a trap with the community

 

name being trap-communitywhen the event occurs. trap-communityrepresents

 

the community name of the network management station that receives trap

 

message, a string of 1 to 127 characters.

 

owner text: Owner of the entry, a string of 1 to 127 characters. It is case sensitive

 

and space is supported.

Description

Use the rmon event command to create an entry in the RMON event table.

 

Use the undo rmon event command to remove a specified entry from the

 

RMON event table.

 

When an event is triggered by its associated alarm in the alarm table, the event

 

group allows you to log it, send a trap, do both, or do neither at all. This helps

 

control the generation and notification of events.

n

When you create an entry, if the values of the specified event description

(description string), event type (log, trap, logtrap or none), and community

 

name (trap-community or log-trapcommunity) are identical to those of the

 

existing event entry, the system considers their configurations the same and the

 

creation fails.

 

You can create up to 60 alarm entries.

Page 2323