673

Description Use the display controller cpos command to display information about CPOS interfaces, such as state of E1/T1 channels, and alarms, and errors occurred to the regeneration section, multiplex section, and higher-order path.

The following table lists possible error types in the displayed information:

Table 121 Possible error types

Field

Description

 

 

FRED

Receive loss of basic frame alignment, or receive frames with red alarm

 

errors.

COFA

Change of frame alignment.

SEF

Severely error frame. Four consecutive frame synchronization errors

 

generate one SEF.

FERR

Framing Bit Error. It refers to the frame with the Ft/FPS/FAS error.

CERR

CRC error

FEBE

Far end block error. This occurs when the CRC4 framing format applies on

 

the E1 channel.

BERR

PRBS bit error (Pseudo-random binary sequence bit error, for test only).

BIP

Bit-interleaved parity.

REI

Remote error indication.

 

 

In this table, FRED, COFA, and SEF are alarm errors (AERRs).

Related command: display controller cpos e1, display controller cpos t1.

Example # Display the path information of interface CPOS 4/0.

<Sysname> display controller cpos 4/0 Cpos4/0 current state : UP Description : Cpos4/0 Interface

Frame-format SDH, multiplex AU-3, clock master, loopback not set

Tx: J0: 0x01, J1: "NetEngine", C2: 0x02

Rx: J0: 0x01, J1: "NetEngine", C2: 0x02

Regenerator section:

Alarm: none

Error: 0 BIP, 0 SEF

Multiplex section:

Alarm: none

Error: 0 BIP, 0 REI

Higher order path(VC-3-1):

Alarm: none

Error: 0 BIP, 0 REI

Higher order path(VC-3-2):

Alarm: none

Error: 0 BIP, 0 REI

Higher order path(VC-3-3):

Alarm: none

Error: 0 BIP, 0 REI

Cpos4/0 CT1 1 is up

Frame-format ESF, clock master, loopback not set

Cpos4/0 CT1 2 is up

Frame-format ESF, clock master, loopback not set

Page 673
Image 673
3Com MSR 50, MSR 30 manual This table, FRED, COFA, and SEF are alarm errors AERRs, Possible error types, 673