1865

undo dar protocol-statistic

View Interface view

Parameters time: Time interval between statistics actions , in minute, in the range 1 to 30. By default, it is 5 minutes.

Description Use the dar protocol-statisticcommand to enable DAR packet statistics function.

Use the undo dar protocol-statisticcommand to disable the function.

With DAR packet statistics function, users can timely monitor the packet number, data stream volume, historical mean rate and historical maximum rate of application protocol on each interface, thus to facilitate implementing corresponding policies for the data streams.

By default, the function is disabled.

Examples # Enable DAR packet statistics function on the interface Ethernet1/0, and set the interval to 7 minutes.

<Sysname> system-view

[Sysname] interface Ethernet 1/0

[Sysname-Ethernet1/0] dar protocol-statistic flow-interval 7

display dar information

Syntax display dar information

View Any view

Parameters None

Description Use the display dar information command to display information about the DAR module.

Examples # Display information about the DAR module.

<Sysname> display dar information

Max session count

: 65536

Watched session count

: 1000

Table 494 Description on the fields of the display dar information command

 

 

Field

Description

 

 

Max session count

The number of maximum sessions

Watched session count

The number of watched sessions

 

 

Page 1865