1865
undo dar protocol-statistic
View Interface view
Parameters time: Time interval between statistics actions , in minute, in the range 1 to 30. By
default, it is 5 minutes.
Description Use the dar protocol-statistic command to enable DAR packet statistics
function.
Use the undo dar protocol-statistic command to disable the function.
With DAR packet statistics function, users can timely monitor the packet number,
data stream volume, historical mean rate and historical maximum rate of
application protocol on each interface, thus to facilitate implementing
corresponding policies for the data streams.
By default, the function is disabled.
Examples # Enable DAR packet statistics function on the interface Ethernet1/0, and set the
interval to 7 minutes.
<Sysname> system-view
[Sysname] interface Ethernet 1/0
[Sysname-Ethernet1/0] dar protocol-statistic flow-interval 7
display dar information
Syntax display dar information
View Any view
Parameters None
Description Use the display dar information command to display information about the
DAR module.
Examples # Display information about the DAR module.
<Sysname> display dar information
Max session count : 65536
Watched session count : 1000
Table494 Description on the fields of the display dar information command
Field Description
Max session count The number of maximum sessions
Watched session count The number of watched sessions