2518 CHAPTER 169: ACSEI SERVER CONFIGURATION COMMANDS

acsei timer clock-sync

Syntax acsei timer clock-sync minutes

undo acsei timer clock-sync

View ACSEI server view

Parameters minutes: Value of the synchronization timer that is used for clock synchronization from ACSEI server to ACSEI client. It ranges from 0 to 1440 (in minutes), where value 0 specifies to inhibit the clock synchronization from ACSEI server to ACSEI client.

Description Use the acsei timer clock-synccommand to set the synchronization timer that is used for clock synchronization from ACSEI server to ACSEI client.

Use the undo acsei timer clock-synccommand to restore the default value for the synchronization timer.

By default, the sychronization timer is set to five minutes.

Examples # Set the synchronization timer from ACSEI server to ACSEI client to 20 minutes.

<Sysname> system-view

[Sysname] acsei server

[Sysname-acsei-server] acsei timer clock-sync 20

acsei timer monitor

Syntax acsei timer monitor seconds

undo acsei timer monitor

View ACSEI server view

Parameters seconds: Value of the monitor timer that is used for ACSEI server to monitor ACSEI clients. It ranges from 0 to 10 (in seconds), where 0 specifies to disable ACSEI server from monitoring ACSEI client.

Description Use the acsei timer monitor command to set the monitor timer for ACSEI server to monitor ACSEI client.

Use the undo acsei timer monitor command to restore the default value for the monitor timer.

By default, the monitor timer is set to five seconds.

Examples # Set the monitor timer for ACSEI server to monitor ACSEI client to six seconds.