254CHAPTER 16: FUNDAMENTAL CE3 INTERFACE CONFIGURATION COMMANDS

Example # Perform BERT test in QRSS mode on CE3 2/0 interface, setting the duration to ten minutes.

<Sysname> system-view

[Sysname] interface E3 2/0

[Sysname-E3 2/0] bert pattern qrss time 10

clock (CE3 interface view)

Syntax

clock { master slave }

 

undo clock

View

CE3 interface view

Parameter

master: Adopts the internal clock as the clock source.

 

slave: Adopts the line clock as the clock source.

Description

Use the clock command to configure clock source for the CE3 interface.

 

Use the undo clock command to restore the default, that is, line clock.

 

The clock source is selected depending on the connected remote device. If

 

connected to a transmission device, the local end uses the line clock. If connected

 

to a CE3 interface on another router, the local end can use whichever clock so

 

long as it is different from the one adopted at the remote end.

Example

# Use the internal clock as the clock source on CE3 interface E3 2/0.

 

<Sysname> system-view

 

[Sysname] controller e3 2/0

 

[Sysname-E3 2/0] clock master

controller e3

Syntax

controller e3 interface-number

View

System view

Parameter

interface-number: CE3 interface number.

Description

Use the controller e3 command to enter CE3 interface view.

Related command:

display controller e3.

Example # Enter the view of interface E3 2/0.

Page 254
Image 254
3Com MSR 30 Clock CE3 interface view, Controller e3, Display controller e3, Example # Enter the view of interface E3 2/0