270CHAPTER 17: FUNDAMENTAL CT3 INTERFACE CONFIGURATION COMMANDS

No code is sent now.

Periodical detection is enabled, no code received now.

BERT state:(stopped, not completed)

Test pattern: 2^7, Status: Not Sync, Sync Detected: 0

Time: 0 minute(s), Time past: 0 minute(s)

Bit errors (since test started): 0 bits

Bits received (since test started): 0 Mbits

Bit errors (since latest sync): 0 bits

Bits received (since latest sync): 0 Mbits

Historical Statistics:

Last clearing of counters: 14:39:02 UTC Sat 06/25/2005

Data in current interval (22 seconds elapsed):

0 Line Code Violations, 0 Far End Block Error

0 C-Bit Coding Violation, 0 P-bit Coding Violation

0 Framing Bit Err, 0 Severely Err Framing Secs

0 C-bit Err Secs, 0 C-bit Severely Err Secs

0 P-bit Err Secs, 0 P-bit Severely Err Secs

0 Unavailable Secs, 0 Line Err Secs

T3 2/0 CT1 1 is up

Frame-format ESF, clock slave, loopback not set

FDL Performance Report is disabled

Transmitter is sending none

Receiver alarm state is none

Line loop back deactivate code using inband signal last sent

BERT state:(stopped, not completed)

Test pattern: 2^11, Status: Not Sync, Sync Detected: 0

Time: 0 minute(s), Time past: 0 minute(s)

Bit errors (since test started): 0 bits

Bits received (since test started): 0 Kbits

Bit errors (since latest sync): 0 bits

Bits received (since latest sync): 0 Kbits

Table 21 Description on the fields of the display controller t3 command

Field

Description

 

 

T3 2/0 current state

Physical state of the interface: up or down

Description : T3 2/0 Interface

Description about the interface

Basic Configuration

Basic configurations of the interface

Work mode

Operating mode of the interface, CT3 or T3.

cable length

Cable length supported by the interface

Frame-format

Frame format: C-bit parity or M23

line code

In this output sample, line code is B3ZS.

Source clock

Clock source used by the interface: master for the

 

internal clock or slave for the line clock

loopback

Loopback setting on the interface: local, remote,

 

payload, or not set

Alarm State

Alarm state

Receiver alarm state

Type of the received alarm: none, LOS, LOF, RAI, or

 

AIS.

 

If a LOS, LOF, AIS was received, RAI would be sent and

 

the screen displayed “Transmitter is sending RAI”

 

instead.

MDL state

MDL state

Page 270