377

<Sysname> display fr map-info

Map Statistics for interface Serial2/0 (DTE) DLCI = 100, IP INARP 100.100.1.1, Serial2/0 create time = 2002/10/21 14:48:44, status = ACTIVE encapsulation = ietf, vlink = 14, broadcast

DLCI = 200, IP INARP 100.100.1.1, Serial2/0 create time = 2002/10/21 14:34:42, status = ACTIVE encapsulation = ietf, vlink = 0, broadcast

DLCI = 300, IP 1.1.1.1, Serial2/0

create time = 2002/10/21 15:03:35, status = ACTIVE encapsulation = ietf, vlink = 15

Table 45 Description on the fields of the display fr map-info command

Field

Description

 

 

Map Statistics for interface

Display the frame relay address map. The interface operates

Serial2/0 (DTE)

in DTE mode.

DLCI = 100, IP INARP

The PVC with DLCI 100 is mapped to remote IP address

100.100.1.1, Serial2/0

100.100.1.1 through INARP. The PVC is configured on the

 

interface Serial2/0 (If the keyword INAPP is not provided,

 

you need to manually configure established address

 

mapping.)

create time = 2002/10/21

Time and date when the map entry was created

14:48:44

 

status = ACTIVE

State of the map entry

encapsulation = ietf

Encapsulation is set to IETF

broadcast

Broadcasts are permitted

 

 

display fr map-info pppofr

Syntax

display fr map-info pppofr [ interface interface-type{ interface-number

 

interface-number.subnumber } ]

View

Any view

Parameter

interface interface-type { interface-number interface-number.subnumber }:

 

Specifies an interface by its type and number. It can be a main or subinterface. The

 

interface-typeargument is an interface type. The interface-numberargument is a

 

main interface number. The subnumber argument is a subinterface number, in the

 

range 0 to 1023.

Description

Use the display fr map-info pppofr command to display current PPP over

 

frame relay (PPPoFR) mappings and their states for the specified or all interfaces.

Example # Display information about current PPPoFR mappings and their states.

<Sysname> display fr map-info pppofr

 

 

Fr Interface

DLCI

Fr State

PPP Interface

PPP Phase

Serial2/0

100

down

Virtual-Template1

Phase:0

Serial2/1

200

down

Virtual-Template2

Phase:0

Page 377
Image 377