240CHAPTER 15: T1-F INTERFACE CONFIGURATION COMMANDS

<Sysname> display ft1 serial 2/0 Serial2/0

Input: 0 packets, 0 bytes

0

broadcasts, 0 multicasts

0

errors, 0 runts, 0 giants

0

CRC, 0 align errors, 0 overruns

0

dribbles, 0 aborts, 0 no buffers

0

frame errors

Output:0

packets, 0 bytes

0

errors, 0 underruns, 0 collisions

0deferred Basic Configuration:

Work mode is T1 framed, Cable type is 100 Ohm balanced. Frame-format is esf, fdl is none, Line code is b8zs. Source clock is slave, Data-coding is normal.

Idle code is ff, Itf type is ff, Itf number is 2 Loop back is not set.

Alarm State:

Receiver alarm state is Loss-of-Signal. Transmitter is sending remote alarm. Pulse density violation detected.

SendLoopCode History:

inband-llb-up:0 times, inband-llb-down:0 times. fdl-ansi-llb-up:0 times, fdl-ansi-llb-down:0 times. fdl-ansi-plb-up:0 times, fdl-ansi-plb-down:0 times.

BERT state:(stopped, not completed)

Test pattern: 2^15, Status: Not Sync, Sync Detected: 0 Time: 0 minute(s), Time past: 0 minute(s)

Bit Errors (since test started): 0 bits

Bits Received (since test started): 0 Kbits

Bit Errors (since latest sync): 0 bits

Bits Received (since latest sync): 0 Kbits Historical Statistics:

Last clearing of counters: Never

Data in current interval (285 seconds elapsed): 0 Line Code Violations, 0 Path Code Violations 0 Ais Alarm Secs, 286 Los Alarm Secs

7 Slip Secs, 286 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins

0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 286 Unavail Secs Data in Interval 1:

0 Line Code Violations, 0 Path Code Violations

0 Ais Alarm Secs, 901 Los Alarm Secs

22 Slip Secs, 901 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins

0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 901 Unavail Secs Data in Interval 2:

0 Line Code Violations, 0 Path Code Violations

0 Ais Alarm Secs, 900 Los Alarm Secs

23 Slip Secs, 900 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins

0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 900 Unavail Secs Total Data (last 2 15 minute intervals):

0 Line Code Violations, 0 Path Code Violations

0 Ais Alarm Secs, 2087 Los Alarm Secs

52 Slip Secs, 2087 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins

0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 2087 Unavail Secs

Table 20 Description on the fields of the display ft1 serial command

Field

Description

 

 

Serial2/0

Interface type and number

Basic Configuration

Basic configurations for the interface

Input

Statistics about the input and output

Output

 

Work mode

T1 interface operating mode, T1 framed in this

 

sample output

Page 240
Image 240
3Com MSR 30, MSR 50 manual Description on the fields of the display ft1 serial command, Field Description