2594 CHAPTER 173: VOIP CONFIGURATION COMMANDS

View

E&M voice subscriber line view

Parameter

delay: When using the delay start mode, the calling end occupies the trunk line,

 

and the called end, such as PBX, will also enter the hook-off state to respond the

 

caller till it is ready for receiving the called number.

 

immediate: Immediate start mode. The caller end hooks off to seize the line

 

through line E and sends the called number. The prerequisite for using the

 

immediate start mode is: The equipment at the remote end should listen to the

 

dial signal immediately after identifying the off-hook signal.

 

wink: Wink start mode. The caller end hooks off to seize the line through line E,

 

and it has to wait for a wink signal from the remote end before sending out the

 

called number.

Description

Use the em-signalcommand to configure a start mode for an analog E&M voice

 

subscriber line.

 

Use the undo em-signalcommand to restore the default start mode.

 

By default, the immediate start mode is selected for the analog E&M subscriber

 

line.

Related command:

delay.

Example

# Configure delay mode.

 

<Sysname> system-view

 

[Sysname] voice-setup

 

[Sysname-voice] subscriber-line 1/0

 

[Sysname-voice-line1/0] em-signal delay

entity

Syntax

entity entity-number{ pots voip }

 

undo entity { entity-numberall pots voip }

View

Voice dial program view

Parameter

entity-number: Identifies a voice entity. The value ranges from 1 to 2147483647.

 

all: All voice entities.

 

pots: Indicates that the voice entity originates a call from the local voice subscriber

 

line.

 

voip: Indicates that the voice entity originates a call from the network side.

Description

Use the entity command to enter voice entity view, or configure a voice entity

 

and then enter its view if the voice entity does not exist.

Page 2594
Image 2594