2504 CHAPTER 166: POE CONFIGURATION COMMANDS

poe pse-policy priority

Syntax

poe pse-policy priority

 

undo poe pse-policy priority

View

System view

Parameter

None

Description

Use the poe pse-policy priority command to configure a PSE power

 

management priority policy.

 

Use the undo poe pse-policy priority command to remove the PSE power

 

management priority policy.

 

By default, no PSE power management priority policy is configured.

Example

# Configure a PSE power management priority policy.

 

<Sysname> system-view

 

[Sysname] poe pse-policy priority

poe update

Syntax

poe update { full refresh } filename [ pse pse-id]

View

System view

Parameter

full: Specifies to upgrade the PSE processing software in full mode when the

 

software is unavailable.

 

refresh: Specifies to upgrade the PSE processing software in refresh mode when

 

the software is available.

 

filename: Name of the upgrade file, a string of 1 to 64 characters. This file must be

 

under the root directory of the file system of the device. The extension of the

 

upgrade file varies with devices.

 

pse pse-id: Specifies a PSE ID. The support for this argument varies with devices.

 

pse-idindicates number of the slot where a PoE interface locates.

Description

Use the poe update command to upgrade the PSE processing software online.

Example

# Upgrade the processing software of PSE 2 online

 

<Sysname> system-view

 

[Sysname] poe update refresh 0400_001.S19 pse 2

Page 2504
Image 2504
3Com MSR 30, MSR 50 Poe pse-policy priority, Undo poe pse-policy priority, Poe update full refresh filename pse pse-id