1971

Related command: reset stop-accounting-buffer,radius scheme, display stop-accounting-buffer.

Example # In RADIUS scheme radius1, enable the device to buffer the stop-accounting requests getting no responses.

<Sysname> system-view

[Sysname] radius scheme radius1

[Sysname-radius-radius1] stop-accounting-buffer enable

timer quiet (RADIUS scheme view)

Syntax timer quiet minutes

undo timer quiet

View RADIUS scheme view

Parameter minutes: Primary server quiet period, in minutes. It ranges from 1 to 255 and defaults to 5.

Description Use the timer quiet command to set the quiet timer for the primary server, that is, the duration that the status of the primary server stays blocked before resuming the active state.

Use the undo timer quiet command to restore the default.

Related command: display radius scheme.

Example # Set the quiet timer for the primary server to 10 minutes.

<Sysname> system-view

[Sysname] radius scheme test1

[Sysname-radius-test1] timer quiet 10

timer realtime-accounting (RADIUS scheme view)

Syntax timer realtime-accounting minutes

undo timer realtime-accounting

View RADIUS scheme view

Parameter minutes: Real-time accounting interval in minutes, must be a multiple of 3 and in the range 3 to 60, with the default value being 12.

Description Use the timer realtime-accountingcommand to set the real-time accounting interval.