221

Table 18 Description on the fields of the display controller t1 command

Field

Description

 

 

Itf number

Number of interframe filling tags

Loop back

Loopback setting on the interface: local, payload, remote,

 

or not set

Alarm State

Alarm state

Receiver alarm state

Type of received alarm: none, LOS, LOF, RAI, or AIS

Transmitter is sending remote

Type of transmitted alarm: RAI, or none

alarm.

 

Pulse density violation detected

The detected pulse density is incompliant with the

 

specification

SendLoopCode History:

inband-llb-up:0 times, inband-llb-down:0 times.

fdl-ansi-llb-up:0 times, fdl-ansi-llb-down:0 times.

fdl-ansi-plb-up:0 times, fdl-ansi-plb-down:0 times

BERT state:(stopped, not completed)

Test pattern: 2^15, Status: Not

Sync, Sync Detected: 0

History of loopback code sending to the far-end, including the number of transmissions for each type of code, and the type of the last sent code. (See “sendloopcode” on page 229.)

BERT state: completed, stopped (not completed), or running.

Test pattern in use (2^20 or 2^15), 2^15 in this example; synchronization state, and the number of detected synchronizations

Time: 0 minute(s), Time past: 0

The duration of the BERT test and the time that has

minute(s)

elapsed

Bit Errors (since test started)

Number of bit errors received since the start of the BERT

 

test

Bits Received (since test started)

Number of bits received since the start of the BERT test

Bit Errors (since latest sync)

Number of bit errors received since the last

 

synchronization

Bits Received (since latest sync)

Historical Statistics:

Last clearing of counters

Data in current interval (285 seconds elapsed):

0 Line Code Violations, 0 Path Code Violations

0 Ais Alarm Secs, 286 Los Alarm Secs

7 Slip Secs, 286 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins

0 Errored Secs, 0 Bursty Err Secs,

0 Severely Err Secs, 286 Unavail

Secs

Number of bits received since last synchronization

Historical statistics

Counter clearing records

Statistics spanning the current interval. The statistical items, such as AIS alarm, LOS signal, and LFA, are provided according to the T1 specifications for the physical layer.

For details, refer to ANSI T1.403 and AT&T TR 54016.

Page 221
Image 221
3Com MSR 50, MSR 30 manual 221