518CHAPTER 31: PPP AND MP CONFIGURATION COMMANDS

Description

Use the ppp mp max-bindcommand to configure the maximum number of

 

links allowed in an MP bundle.

 

Use the undo ppp mp max-bindcommand to restore the default value, which

 

is 16.

 

Generally speaking, it is unnecessary to configure this argument, but in case you

 

need to configure it, you must do it under the guidance of technical engineers.

 

Such a configuration may affect the performance of PPP.

n

If MP fails to delete links, it is possibly because that the maximum number of

bundled links is smaller than what has actually been configured. Make sure

 

that the maximum binding number is larger than the actual one.

 

After you change the maximum number of bundled links in an MP on a

 

virtual-template or dialer interface, you must shutdown and then undo

 

shutdown the relevant physical interfaces before modification takes effect.

Related command:

ppp mp.

Example

# Set the maximum number of binding links to 12.

 

<Sysname> system-view

 

[Sysname] interface virtual-template 0

 

[Sysname-Virtual-Template0] ppp mp max-bind 12

 

 

ppp mp min-bind

 

Syntax

ppp mp min-bind min-bind-num

 

undo ppp mp min-bind

View

Dialer interface view

Parameter

min-bind-num: Specifies the minimum number of links in an MP bundle, in the

 

range 1 to 128.

Description

Use the ppp mp min-bindcommand to configure the minimum number of PPP

 

links that an MP bundle should contain.

 

Use the undo ppp mp min-bindcommand to restore the default value.

 

By default, the minimum number of PPP links in an MP bundle is 0, which means

 

that MP dial-up relies on traffic detection.

 

In dial-up application, you sometimes need multiple links to bear services

 

simultaneously to guarantee the minimum bandwidth in transmitting a packet. In

 

this case, you can use this command to set the minimum links to be bound.

 

Note that, after you configure the ppp mp min-bindcommand, MP dial-up no

 

longer depends on traffic detection. Moreover, links that have been established

 

will not be removed even in case of timeout. This means that after the ppp mp

Page 518
Image 518
3Com MSR 30, MSR 50 manual Related command Ppp mp Example, Ppp mp min-bind min-bind-num, Undo ppp mp min-bind