1362 CHAPTER 88: IGMP CONFIGURATION COMMANDS

 

Use the undo timer other-querier-presentcommand to restore the system

 

default.

 

By default, the IGMP other querier present interval is [ IGMP query interval ] times

 

[ IGMP querier robustness variable ] plus [ maximum response time for IGMP

 

general queries ] divided by two.

n

The three parameters in the above-mentioned formula default to 60 (seconds), 2

(times) and 10 (seconds) respectively, so the default other querier present interval

 

= 60 2 + 10 / 2 = 125 (seconds).

Related command:

igmp timer other-querier-present,timer query (IGMP view), robust-count

 

(IGMP view), max-response-time (IGMP view), display igmp interface.

Example

# Set the global value of the other querier present interval to 200 seconds in the

 

public instance.

 

<Sysname> system-view

 

[Sysname] igmp

 

[Sysname-igmp] timer other-querier-present 200

timer query (IGMP view)

Syntax timer query interval

undo timer query

View Public instance IGMP view, VPN instance IGMP view

Parameter interval: IGMP query interval in seconds, namely interval between IGMP general queries sent by the querier, with an effective range of 1 to 18,000.

Description Use the timer query command to configure the IGMP query interval globally.

Use the undo timer query command to restore the default setting.

By default, IGMP query interval is 60 seconds.

Related commands: igmp timer query, timer other-querier-present (IGMP view), display igmp interface.

Example # Set the global value of the IGMP query interval to 125 seconds in the public instance.

<Sysname> system-view [Sysname] igmp [Sysname-igmp] timer query 125

Page 1362
Image 1362
3Com MSR 30, MSR 50 manual Timer query Igmp view, Public instance, Syntax timer query interval Undo timer query