153

RMON CONFIGURATION COMMANDS

display rmon alarm

Syntax display rmon alarm [ entry-number]

View Any view

Parameter entry-number: Index of an RMON alarm entry, in the range 1 to 65535. If no entry is specified, the configuration of all alarm entries is displayed.

Description Use the display rmon alarm command to display the configuration of the specified or all RMON alarm entries.

Related command: rmon alarm.

Example # Display the configuration of all RMON alarm table entries.

<Sysname> display rmon alarm

Alarm table 1 owned by user1 is VALID.

Samples type

 

: absolute

Variable formula

: 1.3.6.1.2.1.16.1.1.1.4.1<etherStatsOctets.1>

Sampling interval

: 10(sec)

Rising threshold

: 50(linked with event 1)

Falling threshold

: 5(linked with event 2)

When startup enables

: risingOrFallingAlarm

Latest value

 

: 0

Table 608 Description on the fields of the display rmon alarm command

 

 

Field

Description

 

 

Alarm table

Alarm entry index, 1 in this example

owned by

Owner of the entry, user1 in this example

VALID

Status of the entry identified by the index (VALID means the entry is

 

valid, and UNDERCREATION means invalid. You can use the display

 

rmon command to view the invalid entry and with the display

 

current-configuration and display this commands you cannot view

 

the corresponding rmon commands.)

Samples type

The sampling type (absolute in this example)

Variable formula

Formula for the sampling value

Sampling interval

Sampling interval

Rising threshold

Alarm rising threshold (When the sampling value is bigger than or

 

equal to this threshold, a rising alarm is triggered.)

Falling threshold

Alarm falling threshold (When the sampling value is smaller than or

 

equal to this threshold, a falling alarm is triggered.)

Page 2315
Image 2315
3Com MSR 50, MSR 30 manual 153, Rmon Configuration Commands, Display rmon alarm, Syntax display rmon alarm entry-number