457

x25 roa-list

Syntax x25 roa-listroa-name roa-id&<1-10>

undo x25 roa-list roa-name

View System view

Parameter roa-name: Name of ROA, a string of 1 to 19 characters.

roa-id&<1-10>: ROA ID. Its value ranges from 0 to 9999. You can specify 10 IDs for the ROA.

Description Use the x25 roa-listcommand to define ROA list.

Use the undo x25 roa-listcommand to delete ROA list items.

By default, no ROA list is defined.

You can configure multiple (0 to 20. The maximum number of ROA lists supported by the system is 1,000) ROAs. After configuring ROA, you can reference it by its name in the commands x25 call-facilityor x25 map.

Related command: x25 call-facility,x25 map.

Example # Define two ROA lists, and apply them to the interfaces Serial 2/0 and Serial 2/1 respectively.

<Sysname> system-view

[Sysname] x25 roa-list list1 11 23 45

[Sysname] x25 roa-list list2 345

[Sysname] interface serial 2/0 [Sysname-Serial2/0] x25 call-facility roa-list list1

[Sysname-Serial2/0] quit [Sysname] interface serial 2/1

[Sysname-Serial2/1] x25 call-facility roa-list list2

x25 switch pvc

Syntax x25 switch pvc pvc-number1 interface interface-type interface-number [ dlci dlci-number ] pvc pvc-number2 [ option ]

undo x25 switch pvc pvc-number1

View Interface view

Parameter pvc-number1: PVC number on the input interface, and its value ranges from 1 to 4095.

Page 457
Image 457
3Com MSR 50, MSR 30 X25 roa-list, X25 switch pvc, Undo x25 roa-list roa-name, Related command x25 call-facility,x25 map