672CHAPTER 45: CPOS INTERFACE CONFIGURATION COMMANDS

Before you can configure a CPOS physical interface, you must enter its CPOS interface view.

Example # Enter the interface view of CPOS 1/0.

<Sysname> system-view [Sysname] controller cpos 1/0 [Sysname-Cpos1/0]

crc

Syntax

crc { 16 32 none }

 

undo crc

View

Synchronizing serial interface view

Parameter

16: Sets the length of the CRC word to 16 bits.

 

32: Sets the length of the CRC word to 32 bits.

 

None: Disables CRC.

Description

Use the crc command to set the CRC word length for a synchronizing serial

 

interface formed by CPOS interfaces.

 

Use the undo crc command to restore the default.

 

The CRC word length for a synchronizing serial interface formed by CPOS

 

interfaces defaults to 16 bits.

Example

# Set the CRC word length to 16 bits for CPOS interface 1/0.

 

<Sysname> system-view

 

[Sysname] controller cpos 1/0

 

[Sysname-Cpos1/0] e1 3 channel-set 1 timeslot-list 1-31

 

[Sysname-Cpos1/0] quit

 

[Sysname] interface serial 1/0/3:1

 

[Sysname-Serial1/0/3:1] crc 16

display controller cpos

Syntax

display controller cpos [ cpos-number]

View

Any view

Parameter

cpos-number: CPOS interface number. If no CPOS number is specified, the

 

information about all CPOS interfaces is displayed.

Page 672
Image 672
3Com MSR 30, MSR 50 manual Display controller cpos cpos-number