466CHAPTER 26: LAPB AND X.25 CONFIGURATION COMMANDS

Example # Set the restart timer on the X.25 interface Serial 2/0 to 120 seconds.

<Sysname> system-view

[Sysname] interface serial 2/0

[Sysname-Serial2/0] x25 timer tx0 120

x25 timer tx1

Syntax x25 timer tx1 seconds

undo x25 timer tx1

View Interface view

Parameter seconds: Time of calling request (indication) sending timer in seconds, ranging from 0 to 1000.

Description Use the x25 timer tx1 command to set calling request (indication) sending timer for the DTE (or DCE).

Use the undo x25 timer tx1 command to restore the default.

By default, the timer time on a DTE is 200 seconds, and that on a DCE is 180 seconds.

According to X.25, a timer should be started when the DTE sends a call request (or the DCE sends a call indication). If no peer acknowledgement is received after the timer timeout, the sending end will take some measures to guarantee the normal proceeding of the local procedure. This parameter specifies the time of this timer.

Related command: x25 timer tx0, x25 timer tx2, x25 timer tx3.

Example # Set calling request (indication) sending timer on the X.25 interface Serial2/0 to 100 seconds.

<Sysname> system-view

[Sysname] interface serial 2/0

[Sysname-Serial2/0] x25 timer tx1 100

x25 timer tx2

Syntax x25 timer tx2 seconds

undo x25 timer tx2

View Interface view

Parameter seconds: Reset request (indication) timer in seconds, ranging from 1 to 1000.

Page 466
Image 466
3Com MSR 30, MSR 50 manual X25 timer tx1, X25 timer tx2, Syntax x25 timer tx1 seconds Undo x25 timer tx1